PARKING GARAGE

NEW YORK CITY

 

 New York City Code:

The requirements of the 1- RCNY 103-13 Chapter 100 for Periodic Inspection of Parking Structures. Parking structure. A building or portion of a building used for the parking or storage of motor vehicles and an open or enclosed parking garage as defined in the New York City Building Code. A parking structure does not include an autobody repair shop, an automotive showroom, a garage with occupancy of fewer than three cars, unenclosed and unattached lots, an automotive service station, an automotive repair shop, or a private garage as such term is defined in the building code. Report filing cycle. The six-year time interval established by the Commissioner for the filing of each successive compliance report for every parking structure subject to the requirements of Article 323 of Title 28 of the Administrative Code. Safe condition. A condition of a parking structure, any appurtenances thereto or any part thereof not requiring repair or maintenance to sustain the structural integrity of the parking structure and that is to remain safe during the next six years. Compliance Report. A report prepared by a qualified parking structure inspector summarizing the condition assessment of the subject parking structure and attesting to its accompanying classification. Qualified Parking Structure Inspector (hereinafter “QPSI”). A qualified parking structure inspector as defined in section 101-07 of the rules of the Department. Owners of buildings in which parking structures are located are required to file a compliance report at least once during each six-year report filing cycle established by the Department.

Periodic inspection requirements. In order to maintain a parking structure and its appurtenances in a safe condition, and in accordance with Article 323 of Title 28 of the Administrative Code, a condition assessment of all components of a parking structure must be conducted at periodic intervals specified herein.

Exceptions: The façade of the structure does not need to be included in the parking structure compliance report if:

1. the building is subject to the Façade Inspection Safety Program (FISP) ; or

2. the parking structure occupies less than 50% of the total square footage of the building.

Examination of a building’s exterior walls and appurtenances thereof pursuant to section 28-302.2 of the Administrative Code must be performed by or under the direct supervision of a QEWI retained by the owner of the building or his or her representative.

Buildings required to file a report must do so at least once during each five-year report filing cycle established by the Department, an acceptable report must be filed within the applicable two-year filing window to avoid a late filing penalty.

 A report must be filed within sixty (60) days of the date on which the QEWI completed the critical examination (final inspection date), failure to file a report within sixty (60) days of the completed critical examination requires a new critical examination. A report may not be filed more than one (1) year after completion of the close-up inspection.

When Conditions that are safe with a repair and maintenance program (SWARMP). The owner of the building is responsible for ensuring that the conditions described in the critical examination report as SWARMP are corrected and all actions recommended by the QEWI are completed within the time frame recommended by the QEWI and are not left to deteriorate into unsafe conditions. It is the owner’s responsibility to notify the Department of any deviation from the timeframe to make corrections as specified in QEWI’s report.

Upon filing a report of an unsafe condition with the Department, the owner of the building, his or her agent, or the person in charge of the building must immediately commence such repairs or reinforcements and any other appropriate measures such as erecting sidewalk sheds, fences, and safety netting as may be required to secure the safety of the public and to make the building's walls and appurtenances conform to the provisions of the Administrative Code. All unsafe conditions must be corrected within ninety (90) days of the submission of the critical examination report. If, due to the scope of the repairs, the unsafe conditions cannot be corrected within the required 90 days, the QEWI must recommend a timeframe for repairs.

The owner of the building is responsible for ensuring that the conditions described in the critical examination report as unsafe are corrected and all actions recommended by QEWI are completed within this timeframe. The owner must notify the Department of any deviation from the timeframe to make corrections as specified in QEWI’s report. The subsequent report must include supporting documents from the QEWI justifying the request for a new time frame.

Sheds or other protective measures must remain in place until an amended report is accepted; however, the QEWI may request permission for the removal of the shed upon submission of a signed and sealed statement certifying that an inspection was conducted, the conditions were corrected, and the shed is no longer required. Permission to remove the shed may be granted at the Commissioner’s sole discretion.

Elements of a Parking Structure

 Appurtenance. An element including, but not limited to, rolldown gates, attendant booths, lighting fixtures, gates, staircases, fire protection, column protection, signs, parapets, railings, guard rails, enclosures, antennae, bollards, vehicle barriers, vehicle impact protection, electric vehicle charging stations, and any other equipment attached to the parking structure. Appurtenance does not include mechanical devices for vehicles moving from and to street levels or within the structure such as parking machines, lifts, mechanical stackers, automated parking systems, and elevators in which public occupancy is prohibited.

 Review of Project Documents

 The known history of the parking structure, the nature of the materials used, and the conditions observed will dictate the extent of the condition assessment. The QPSI must apply a professional standard of care to assess the structure’s condition and the individual building systems that comprise the structure including, but not limited to, the building’s structural components, waterproofing systems, fireproofing and fire stopping systems, and wearing surfaces. When the QPSI finds any deficiencies, he/she must ascertain the cause of these and any other possible building defects detected. The QPSI must order any special or additional inspections, probes, and/or tests, including sounding procedures, that may be required to support the condition assessment and to determine the causes of any defects.

 1. Work permit numbers relating to parking structure repairs;

2. Job numbers, status and sign-off dates for any parking structure repair related jobs, where applicable; and

3. Violation numbers of any open Environmental Control Board (“ECB”) violations and the status of the repairs of the conditions cited in the ECB violations that are directly associated with the parking structure;

 Condition assessment. An examination conducted to review a parking structure and all parts thereof, as defined in Article 323 of title 28 of the Administrative Code, to determine whether the parking structure and all parts thereof are either safe, unsafe, or safe with repairs and/or engineering monitoring and whether, in the judgment of a qualified parking structure inspector, remedial work is required.

 The methods used to evaluate the parking structure in question must permit a complete physical examination of the structure, including, but not limited to, sounding, load tests, optical survey, non-invasive scanning, and cores. The QPSI must identify the most deleterious locations and perform physical examinations at those locations. Physical examinations as described in this rule must be performed on a minimum of 10% of each structural element including, but not limited to, beams, columns, and slabs.

 Upon discovery of any unsafe condition, the QPSI must immediately notify the Department and the owner of the building in which the parking structure is located. The QPSI must identify the location of any unsafe condition, advise the owner on the appropriate protective measures to be taken, and include the recommended type and location of public protection in the notification to the Department.

Filed report. A compliance report shall be deemed filed with the Department when it has been received by the Department. The filed report must be completed in accordance with the provisions of paragraph (3) of subdivision (c) of this section.

 Amended report. A compliance report filed by a qualified parking structure inspector (1) certifying that the unsafe conditions identified in the most recent report have been repaired and that no unsafe conditions exist at the parking structure or (2) attesting, within three years of the most recent safe with repair and/or engineering monitoring (SREM) filing, to the current status of the building based on a condition assessment.

 Safe with repairs and/or engineering monitoring (hereinafter “SREM”). A condition of a parking structure, any appurtenances thereto or any part thereof that is safe at the time of inspection but requires repairs or maintenance during the next one to six years in order to prevent its deterioration into an unsafe condition during that six-year period.

 Unsafe condition. A condition of a parking structure, any appurtenances thereto, or any part thereof that is hazardous to persons or property and requires repair within one year of completion of condition assessments. In addition, any condition that was reported as SREM in a previous compliance report and that is not corrected at the time of the current inspection must be reported as an unsafe condition.

 The QPSI must develop a unique annual observation checklist, as defined in 28-323.2 of the Administrative Code, during each condition assessment.

 The QPSI must file with the Department a written compliance report describing the result of the condition assessment, clearly documenting all conditions noted during the inspection, including the physical examination, and stating that the inspection was performed and completed in accordance with Article 323 of Title 28 of the Administrative Code and this rule. The QPSI must also submit a copy of the report to the owner of the building in which the parking structure is located.

 The report must include an executive overview that consists of a summary of findings and recommendations, a concise statement of the scope of the inspection and findings, the conclusions and recommendations and a determination as to whether the parking structure is categorized as “safe,” “SREM,” or “unsafe.” The report must also include, but not be limited to:

 A detailed description of any distress, settlements, repairs, or revisions to the structure since the previous compliance report, including, but not limited to, deteriorated framing members, deteriorated joint material, displacement, cracking, spalling of parking structure components, or other defects or changes;

 A description, classification, and mapping of each significant condition observed including deterioration and any movement detected and the apparent integrity of the joints and wearing surfaces. The description must also include a list of all appurtenances and their condition. Each condition must be classified as safe, unsafe or SREM. If the parking structure is classified as unsafe or SREM, the compliance report must include the locations and descriptions of all unsafe or SREM conditions. If unsafe conditions are noted, the report must recommend the type and location of public protection or clearly delineate the extent of areas that have been cordoned off and the methods used. Photographs must be labelled and the report must include key plans and locator drawings documenting these conditions. Guards and railings must be inspected to ensure that their components (balusters, intermediate railings and panel fillers) are positively secured against movement (e.g. by welds, bolts or screws). If any guard or railing is found not to be positively secured, the condition is classified as unsafe and must be made safe pursuant to the requirements of paragraph (5) of subdivision (c) of this section;

 1. If a parking structure is categorized as SREM:

A. The recommended time frame for such repairs or maintenance to be performed, which must indicate the date by which the work must be performed (MM/DD/YYYY) to prevent the conditions from becoming unsafe and not the date on which work is planned or scheduled;

 2. If a parking structure is categorized as unsafe:

A. The QPSI must provide a recommended time frame for repairs to be performed to bring the parking structure to SREM or safe status, and must indicate the date by which the work will be completed (MM/DD/YYYY);

 A list and description of the work permits required to accomplish the necessary work. If no work permits will be required, the reason must be indicated;

 The classification of the parking structure for the current report filing cycle, as determined by the following guidelines:

1. If there are no unsafe conditions and no conditions that are SREM, then the parking structure shall be classified as safe;

2. If there is at least one unsafe condition, then the parking structure must be classified as unsafe.

3. If there is at least one condition that is SREM and there are no unsafe conditions, then the parking structure shall be classified as SREM. A compliance report may not be filed describing the same condition at the same location as SREM for two consecutive report filing cycles. The QPSI must certify that all of the conditions identified in the previous report as requiring repair have been corrected or the parking structure shall be classified as unsafe;

 A report must be filed within 60 days of the date on which the QPSI completed the condition assessment (final inspection date), as described in subparagraph (ix) of paragraph (2) of subdivision (c) of this section. Failure to file a report within 60 days of the completed condition assessment requires a new condition assessment.

 Repairs Monitoring:  

 Upon filing a report of an unsafe condition with the Department, the owner of the building in which the parking structure is located, his or her agent, or the person in charge of the building in which the parking structure is located must immediately commence such repairs or reinforcements and any other appropriate measures such as cordoning off areas that may be dangerous, erecting fences, sidewalk sheds and safety netting as may be required to secure the safety of the public and to make the building's structure and appurtenances conform to the provisions of the Administrative Code.

 All unsafe conditions must be corrected within 90 days from the submission of the compliance report. If, due to the scope of the repairs, the unsafe conditions cannot be corrected within the required 90 days, the QPSI must recommend a timeframe for repairs as noted in item (N) of subparagraph (iii) of paragraph (3) of subdivision (c). The owner of the building in which the parking structure is located is responsible for ensuring that the conditions described in the compliance report as unsafe are corrected and all actions recommended by the QPSI are completed within this timeframe. The owner must notify the Department of any deviation from the timeframe to make corrections as specified in the QPSI’s report. The subsequent report must include supporting documents from the QPSI justifying the request for a new time frame.

 Within two weeks after repairs to correct the unsafe condition have been completed, the QPSI must inspect the premises. The QPSI must promptly file with the Department a detailed amended report stating the revised report status of the parking structure, along with a filing fee as specified in the rules of the Department and the owner must obtain permit sign-offs as appropriate. If the report is not acceptable and is rejected by the  department, a revised report must be filed within 45 days of the date of the Department's rejection after which the original filing date will no longer be valid. If the report is not acceptable after two rejections, a new amended filing fee as specified in the rules of the Department is required. Protective measures must remain in place until an amended report is accepted; however, the QPSI may request permission for the removal of the protective measures, shoring or any other public safety measures upon submission of a signed and sealed statement certifying that an inspection was conducted, the conditions were corrected, and the protective measures are no longer required.

 Conditions that are safe with repairs and/or engineering monitoring (SREM):

 (i) The owner of the building in which the parking structure is located is responsible for ensuring that the conditions described in the compliance report as SREM are corrected and all actions recommended by the QPSI are completed within the time frame recommended by the QPSI and are not left to deteriorate into unsafe conditions. It is the owner’s responsibility to notify the Department of any deviation from the timeframe to make corrections as specified in the QPSI’s report. The subsequent report must include supporting documents from the QPSI justifying the request for a new time frame.

(ii) A condition assessment is required within three years of the initial filing date and an amended report detailing the results of that assessment must be filed with the Department in accordance with section 28-323.9.1 of the Administrative.

 The QPSI must certify the correction of each condition reported as requiring repair in the previous report filing cycle, report conditions that were reported as SREM in the previous report filing cycle as unsafe if not corrected at the time of the current inspection, or report corrections that were made in the previous cycle as unsafe if they need further or repeated repair at the time of the current cycle.

 Annual observation. A building owner is responsible to have an annual observation performed in accordance with the provisions of section 28-323.4 of the Administrative Code. Such annual observation must be based on the checklist included in the most recent compliance report accepted by the Department and as described in section 28-323.2 of the Administrative Code.

(1) This checklist is to be completed annually by or under the direct supervision of a QPSI on behalf of the owner each year after submission of the current cycle's report has been accepted and must be filed with the next cycle's report.

(2) The completed checklists must be kept on site and be made available to the Department and the QPSI upon request.